{"id":2385,"date":"2026-07-09T08:42:34","date_gmt":"2026-07-09T00:42:34","guid":{"rendered":"https:\/\/metalstampingparts.ltd\/?page_id=2385"},"modified":"2026-07-09T08:42:34","modified_gmt":"2026-07-09T00:42:34","slug":"stamped-parts-inspection-fixture-ownership-calibration-guide","status":"publish","type":"page","link":"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/","title":{"rendered":"Stamped Parts Inspection Fixture Ownership and Calibration Guide"},"content":{"rendered":"<p><strong>Short answer:<\/strong> Inspection fixture ownership for stamped parts should define who pays for the fixture, who stores it, how it is calibrated, when gage R&#038;R is needed, how revisions are handled, and what happens during supplier transfer. A fixture is part of the production control plan, not just a shop tool.<\/p>\n<p>Many stamped parts disputes start with measurement method. The supplier uses one fixture, receiving uses another setup, and both teams believe they are measuring the drawing correctly. Fixture ownership and calibration rules reduce that risk before production begins.<\/p>\n<p>Use this guide with the <a href=\"\/buyer-supplier-gage-correlation-stamped-parts-guide\/\">gage correlation guide<\/a>, <a href=\"\/stamped-part-critical-dimensions-inspection-plan\/\">critical dimensions inspection plan<\/a>, <a href=\"\/stamped-parts-ppap-fai-evidence-request-guide\/\">PPAP and FAI evidence guide<\/a>, and <a href=\"\/metal-stamping-tool-ownership-transfer-guide\/\">tool ownership transfer guide<\/a>.<\/p>\n<h2>Fixture and gage control items<\/h2>\n<table class=\"msp-content-table\">\n<thead>\n<tr>\n<th>Item<\/th>\n<th>Why it matters<\/th>\n<th>RFQ detail to confirm<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Ownership and access<\/td>\n<td>A buyer-owned fixture may need transfer rights.<\/td>\n<td>Owner, asset ID, storage location, access rule, and return condition.<\/td>\n<\/tr>\n<tr>\n<td>Calibration and maintenance<\/td>\n<td>Uncontrolled gages can create false rejects or false accepts.<\/td>\n<td>Calibration interval, standard, wear check, repair rule, and record owner.<\/td>\n<\/tr>\n<tr>\n<td>Measurement correlation<\/td>\n<td>Supplier and buyer results must be comparable.<\/td>\n<td>Datum setup, clamp force, burr side, coating condition, and gage R&amp;R when needed.<\/td>\n<\/tr>\n<tr>\n<td>Revision control<\/td>\n<td>A drawing change may make the fixture obsolete.<\/td>\n<td>Revision label, affected features, modification approval, and old fixture quarantine.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Decide whether the fixture is buyer-owned or supplier-owned<\/h2>\n<p>If the fixture is charged to the buyer, the quote should state whether the buyer owns it, whether it can be moved, and whether the supplier may use it for other programs. Ownership should not be inferred from an invoice line.<\/p>\n<p>If the supplier owns the fixture, clarify what measurement evidence the buyer can request and what happens if the part is transferred to another supplier later.<\/p>\n<h2>Define the actual measurement condition<\/h2>\n<p>A stamped part can measure differently depending on fixture restraint, datum selection, burr side, coating thickness, spring force, and whether the part is checked before or after forming recovery.<\/p>\n<p>For flexible or thin parts, ask whether the fixture represents free-state condition or assembly condition. The wrong choice can approve parts that fail in use or reject parts that would assemble correctly.<\/p>\n<p>Record that decision in the inspection plan, not only in email. The same fixture can produce different decisions if operators do not know the intended condition.<\/p>\n<h2>Keep calibration records tied to release evidence<\/h2>\n<p>Calibration records should be available for critical fixtures before first article approval and during production audits. The record should identify the fixture, date, standard used, result, next due date, and any repair or adjustment.<\/p>\n<p>When special gages are used for PPAP or FAI, include their status in the approval file. A passing report from an overdue or modified fixture is weak evidence.<\/p>\n<h2>Plan for supplier transfer before transfer happens<\/h2>\n<p>When a program changes suppliers, fixtures can become a bottleneck. Ask whether fixtures are physically transferable, whether digital files exist, whether calibration history follows the asset, and whether the new supplier needs correlation runs.<\/p>\n<p>Use the <a href=\"\/metal-stamping-supplier-transfer-checklist\/\">supplier transfer checklist<\/a> and <a href=\"\/stamped-parts-supplier-exit-transition-checklist\/\">supplier exit transition checklist<\/a> when fixture movement affects production continuity.<\/p>\n<h2>Control revision updates and obsolete fixtures<\/h2>\n<p>A drawing revision may change datum, tolerance, coating, bend condition, or inspection frequency. The fixture should be reviewed whenever the controlled drawing changes, not only when a dimension looks different.<\/p>\n<p>Old fixtures should be labeled, quarantined, modified, or retired. Leaving two similar fixtures in use is a common way to create mixed inspection evidence.<\/p>\n<h2>RFQ details to include<\/h2>\n<p>Send critical feature list, datum scheme, expected fixture type, buyer ownership requirement, calibration standard, gage R&#038;R need, sample approval level, and supplier transfer rights if relevant.<\/p>\n<p>Send fixture requirements through the <a href=\"\/contact\/\">contact page<\/a>. Use the <a href=\"\/contact\/\">RFQ form<\/a> to request fixture cost, ownership, calibration, and correlation assumptions with the quote.<\/p>\n<h2>Buyer file to keep with the quote<\/h2>\n<p>Keep this stamped parts inspection fixture ownership and calibration guide with the drawing revision, quote number, supplier assumptions, owner of each open action, and the latest approval record. That file helps future supplier reviews, audits, reorders, and transition decisions stay consistent.<\/p>\n<h2>FAQ<\/h2>\n<div itemscope itemtype=\"https:\/\/schema.org\/FAQPage\">\n<div itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\">\n<h3 itemprop=\"name\">Who should own an inspection fixture?<\/h3>\n<div itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n<p itemprop=\"text\">Ownership depends on program risk, cost, transfer needs, and customer rules. If the buyer pays for it, ownership and transfer rights should be written clearly.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\">\n<h3 itemprop=\"name\">When is gage R&amp;R needed?<\/h3>\n<div itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n<p itemprop=\"text\">Gage R&amp;R is useful when a fixture controls critical dimensions, supplier-buyer correlation risk is high, or customer approval requires measurement system evidence.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\">\n<h3 itemprop=\"name\">Can a fixture be transferred to a new supplier?<\/h3>\n<div itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n<p itemprop=\"text\">Sometimes. Transfer depends on ownership, physical condition, calibration status, fixture files, and whether the new supplier can correlate results.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<div itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\">\n<h3 itemprop=\"name\">What should be in the RFQ?<\/h3>\n<div itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n<p itemprop=\"text\">Include critical features, datum setup, fixture ownership, calibration interval, approval evidence, transfer rights, and any customer measurement standard.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/div>\n<p><script type=\"application\/ld+json\"><\/p>\n<p>{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Who should own an inspection fixture?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ownership depends on program risk, cost, transfer needs, and customer rules. If the buyer pays for it, ownership and transfer rights should be written clearly.\"}},{\"@type\":\"Question\",\"name\":\"When is gage R&R needed?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Gage R&R is useful when a fixture controls critical dimensions, supplier-buyer correlation risk is high, or customer approval requires measurement system evidence.\"}},{\"@type\":\"Question\",\"name\":\"Can a fixture be transferred to a new supplier?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Sometimes. Transfer depends on ownership, physical condition, calibration status, fixture files, and whether the new supplier can correlate results.\"}},{\"@type\":\"Question\",\"name\":\"What should be in the RFQ?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Include critical features, datum setup, fixture ownership, calibration interval, approval evidence, transfer rights, and any customer measurement standard.\"}}]}<\/p>\n<p><\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A quality and sourcing guide for controlling inspection fixtures and gages used on stamped parts programs.<\/p>\n","protected":false},"author":1,"featured_media":1825,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2385","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Stamped Parts Inspection Fixture Guide<\/title>\n<meta name=\"description\" content=\"Clarify stamped parts inspection fixture ownership, calibration, gage R&amp;R, storage, transfer, maintenance, and revision control before production.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Stamped Parts Inspection Fixture Guide\" \/>\n<meta property=\"og:description\" content=\"Clarify stamped parts inspection fixture ownership, calibration, gage R&amp;R, storage, transfer, maintenance, and revision control before production.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"Dongguan Chenghui Intelligent Technology Co., Ltd. - Metal Stamping\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61579126831477\" \/>\n<meta property=\"og:image\" content=\"https:\/\/metalstampingparts.ltd\/wp-content\/uploads\/2026\/04\/metal-stamping-assembly-guide-featured-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@duoshaomali\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/stamped-parts-inspection-fixture-ownership-calibration-guide\\\/\",\"url\":\"https:\\\/\\\/metalstampingparts.ltd\\\/stamped-parts-inspection-fixture-ownership-calibration-guide\\\/\",\"name\":\"Stamped Parts Inspection Fixture Guide\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/stamped-parts-inspection-fixture-ownership-calibration-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/stamped-parts-inspection-fixture-ownership-calibration-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/metalstampingparts.ltd\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/metal-stamping-assembly-guide-featured-1.webp\",\"datePublished\":\"2026-07-09T00:42:34+00:00\",\"description\":\"Clarify stamped parts inspection fixture ownership, calibration, gage R&R, storage, transfer, maintenance, and revision control before production.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/stamped-parts-inspection-fixture-ownership-calibration-guide\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/metalstampingparts.ltd\\\/stamped-parts-inspection-fixture-ownership-calibration-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/stamped-parts-inspection-fixture-ownership-calibration-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/metalstampingparts.ltd\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/metal-stamping-assembly-guide-featured-1.webp\",\"contentUrl\":\"https:\\\/\\\/metalstampingparts.ltd\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/metal-stamping-assembly-guide-featured-1.webp\",\"width\":800,\"height\":600,\"caption\":\"Metal stamping assembly line showing welding and joining operations for stamped components\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/stamped-parts-inspection-fixture-ownership-calibration-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/metalstampingparts.ltd\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Stamped Parts Inspection Fixture Ownership and Calibration Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/#website\",\"url\":\"https:\\\/\\\/metalstampingparts.ltd\\\/\",\"name\":\"Dongguan Chenghui Intelligent Technology Co., Ltd. - Metal Stamping\",\"description\":\"Custom Precision Metal Stamping &amp; Hardware Components\",\"publisher\":{\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/metalstampingparts.ltd\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/#organization\",\"name\":\"Dongguan Chenghui Intelligent Technology Co., Ltd. - Metal Stamping\",\"url\":\"https:\\\/\\\/metalstampingparts.ltd\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/metalstampingparts.ltd\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/logo-compressed.jpg\",\"contentUrl\":\"https:\\\/\\\/metalstampingparts.ltd\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/logo-compressed.jpg\",\"width\":200,\"height\":200,\"caption\":\"Dongguan Chenghui Intelligent Technology Co., Ltd. - Metal Stamping\"},\"image\":{\"@id\":\"https:\\\/\\\/metalstampingparts.ltd\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=61579126831477\",\"https:\\\/\\\/x.com\\\/duoshaomali\"],\"knowsAbout\":[\"Metal Stamping\",\"Progressive Die Stamping\",\"Deep Draw Stamping\",\"Sheet Metal Forming\",\"Stamping Die Design\",\"Precision Metal Parts Manufacturing\",\"Aluminum Stamping\",\"Stainless Steel Stamping\",\"Automotive Metal Components\",\"Aerospace Precision Parts\",\"CNC Tooling\",\"Quality Control and Inspection\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Stamped Parts Inspection Fixture Guide","description":"Clarify stamped parts inspection fixture ownership, calibration, gage R&R, storage, transfer, maintenance, and revision control before production.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/","og_locale":"en_US","og_type":"article","og_title":"Stamped Parts Inspection Fixture Guide","og_description":"Clarify stamped parts inspection fixture ownership, calibration, gage R&R, storage, transfer, maintenance, and revision control before production.","og_url":"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/","og_site_name":"Dongguan Chenghui Intelligent Technology Co., Ltd. - Metal Stamping","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61579126831477","og_image":[{"width":800,"height":600,"url":"https:\/\/metalstampingparts.ltd\/wp-content\/uploads\/2026\/04\/metal-stamping-assembly-guide-featured-1.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_site":"@duoshaomali","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/","url":"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/","name":"Stamped Parts Inspection Fixture Guide","isPartOf":{"@id":"https:\/\/metalstampingparts.ltd\/#website"},"primaryImageOfPage":{"@id":"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/#primaryimage"},"image":{"@id":"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/metalstampingparts.ltd\/wp-content\/uploads\/2026\/04\/metal-stamping-assembly-guide-featured-1.webp","datePublished":"2026-07-09T00:42:34+00:00","description":"Clarify stamped parts inspection fixture ownership, calibration, gage R&R, storage, transfer, maintenance, and revision control before production.","breadcrumb":{"@id":"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/#primaryimage","url":"https:\/\/metalstampingparts.ltd\/wp-content\/uploads\/2026\/04\/metal-stamping-assembly-guide-featured-1.webp","contentUrl":"https:\/\/metalstampingparts.ltd\/wp-content\/uploads\/2026\/04\/metal-stamping-assembly-guide-featured-1.webp","width":800,"height":600,"caption":"Metal stamping assembly line showing welding and joining operations for stamped components"},{"@type":"BreadcrumbList","@id":"https:\/\/metalstampingparts.ltd\/stamped-parts-inspection-fixture-ownership-calibration-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/metalstampingparts.ltd\/"},{"@type":"ListItem","position":2,"name":"Stamped Parts Inspection Fixture Ownership and Calibration Guide"}]},{"@type":"WebSite","@id":"https:\/\/metalstampingparts.ltd\/#website","url":"https:\/\/metalstampingparts.ltd\/","name":"Dongguan Chenghui Intelligent Technology Co., Ltd. - Metal Stamping","description":"Custom Precision Metal Stamping &amp; Hardware Components","publisher":{"@id":"https:\/\/metalstampingparts.ltd\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/metalstampingparts.ltd\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/metalstampingparts.ltd\/#organization","name":"Dongguan Chenghui Intelligent Technology Co., Ltd. - Metal Stamping","url":"https:\/\/metalstampingparts.ltd\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/metalstampingparts.ltd\/#\/schema\/logo\/image\/","url":"https:\/\/metalstampingparts.ltd\/wp-content\/uploads\/2026\/05\/logo-compressed.jpg","contentUrl":"https:\/\/metalstampingparts.ltd\/wp-content\/uploads\/2026\/05\/logo-compressed.jpg","width":200,"height":200,"caption":"Dongguan Chenghui Intelligent Technology Co., Ltd. - Metal Stamping"},"image":{"@id":"https:\/\/metalstampingparts.ltd\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=61579126831477","https:\/\/x.com\/duoshaomali"],"knowsAbout":["Metal Stamping","Progressive Die Stamping","Deep Draw Stamping","Sheet Metal Forming","Stamping Die Design","Precision Metal Parts Manufacturing","Aluminum Stamping","Stainless Steel Stamping","Automotive Metal Components","Aerospace Precision Parts","CNC Tooling","Quality Control and Inspection"]}]}},"_links":{"self":[{"href":"https:\/\/metalstampingparts.ltd\/wp-json\/wp\/v2\/pages\/2385","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/metalstampingparts.ltd\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/metalstampingparts.ltd\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/metalstampingparts.ltd\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/metalstampingparts.ltd\/wp-json\/wp\/v2\/comments?post=2385"}],"version-history":[{"count":1,"href":"https:\/\/metalstampingparts.ltd\/wp-json\/wp\/v2\/pages\/2385\/revisions"}],"predecessor-version":[{"id":2386,"href":"https:\/\/metalstampingparts.ltd\/wp-json\/wp\/v2\/pages\/2385\/revisions\/2386"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/metalstampingparts.ltd\/wp-json\/wp\/v2\/media\/1825"}],"wp:attachment":[{"href":"https:\/\/metalstampingparts.ltd\/wp-json\/wp\/v2\/media?parent=2385"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}